Products - Surge Proctect Device for Power Distribution System
Surge Proctect Device for Power Distribution System

Power Surge Protector

Product Details


Surge Proctect Device for Power Distribution System


1.Application:
Expensive electronic equipment is being increasingly used in all kinds of business, industry, government and enterprise anddomestic households. Electronic discharge, over voltage cause by switching or by lightning often cause these highly sensitiveunits to fail.
Electronic equipment is especially prone up to 1.5km way from lightning strikes due to the electromagnetic fields and cable-bome over voltages. However, effective protection is now available.
Over voltage protective devices for TN-S,TN-C,TN-C-S,TT and IT power systems and plants are subdivided into Classes A,B,Cand D depending on their application area, accordingly to DIN VDE 0675-6 (11.89). Compex offers over voltage protective devicesfor Classes B to D, witch cover the complete installation on the low volage side.

2.Feature:
Metal-oxide varistor Arresters still work after frequent operation
An arrester module can be changed with the mains voltage on
1-4 pole Pre-wired arrester blocks Simple installation via the marked terminals
Thermal isolating device with optical indication, permanent check of arrester serviceability
An extremely short response time, a low protection level and a high current diversion capacity combined with long life.
No follow-up current can be registered after the surge has decayed.
If the surge arrester is damaged by overloading, the integral isolating device breaks the connectionto the mains. This is signalled by a red fault indicator.

3.Mounting:
The surge arrestor can easily be installed in any distribution box or switchgear cabinet by snap-fitting to any commercial 35 mmtophat rail. The multi-pole arresters are connected together by an earthing bridge at the factory, so that there is only one earth (PE)connection to make on site.


4.BY1-B/4-385-30 & BY1-B/4-385-40

Type

BY1-B/4-385-30

BY -40

Class

B

B

Rated voltage Un(V)

220/380

220/380

Maximum continuous operating voltage Us (V)

385

385

Protection level Up(KV)

≤2.0

≤2.0

Nominal discharge current (8/20uS) In (KA)

30

40

Max discharge current (8/20uS) Imax (KA)

60

80

Response time T (ns)

<25

<25

Temperature range

-40oC +80oC

-40oC~ +80oC

Color (module/base)

Orange red/gray

Orange red/gray

Material

PBT

PBT

Back up fuse

63A gl

63A gl

With alarm model

BY1-B/4-385-30B

BY1-B/4-385-40B

With remote control contact model

BY1-B/4-385-30X

BY1-B/4-385-40X


5.BY2-30 & BY2-60 

Type

BY2-30

BY2-60

Test class

I

I

class

B

B

Rated voltage Un (V)

220/380

220/380

Max continuous operating voltage Uc (V)

420

420

Insulated resistance Riso ( Ω)

≥1010 

≥1010 

Protection level Up (KV)

≤4.0

≤4.0

Nominal DC spark voltage Un (KA)

2.95KV (+25%/-40% )

2.95KV (+25%/-40% )

Nominal discharge current (8/20uS) In (KA)

30

60

Charge Q (As)

15

30

Power W/R (KJ/Ω)

225

900

Response time T (ns)

<100

<100

Air humidity

≤95%

≤95%

Temperature range

-40oC~ +80oC

-40oC~ +80oC

Protection grade

IP20

IP20

Max back up fuse

205A gl

205A gl


6.BY4-60 & BY4-80,BY4-100 

Model

BY4-60

BY4-80

BY4-100

Test to

IEC61643-1

IEC61643-1

IEC61643-1

class

B

B

B

Rated voltage Un (V)

220/380

220/380

220/380

Max continuous operating voltage Uc (V)

385

385

385

Shock current limp (10/35uS) (KA)

7.5

12

15

Charge Q (As)

2.5

3.75

5

Protection level Up (KV)

≤2.0

≤2.5

≤3.0

Maximum discharge current Imax (8/20uS) (KA)

60

80

100

Nominal discharge current (8/20uS) In (KA)

30

40

60

Response time T (ns)

<25

<25

<25

Color (module/base)

Orange red/gray

Orange red/gray

Orange red/gray

Temperature range

-40oC~ +80oC

-40oC~ +80oC

-40oC~ +80oC

Protection grade

IP20

IP20

IP20

Max back up fuse

63~100A gl

63~100A gl

63~100A gl


7.BY1-C

Type

BY1-C

Class

C

Rated voltage Un (V)

110

220/380

Max continuous operating voltage Uc (V)

140

275

320

385

420

550

Protection level Up (KV)

≤0.8

≤1

≤1.5

≤2.0

≤2.5

Max discharge current Imax (8/20uS) (KA)

40

Nominal discharge current (8/20uS) In (KA)

20

Response time T (ns)

<25

Temperature range

-40oC~ +80oC

Material

PBT

Color (module/ base)

Grey/gray

Max back up fuse

32A gl

Normal model

BY1-C/4-420-20,BY1-C/4-385-20

With alarm model

BY1-C/4-420-20B

With remote control contact model

BY1-C/4-420-20X

Single phase 2P combined to single phase system

BY1-C/2-320-20


8.BY1-C/3+1-320-20 & BY1-C/2+1-320-20

Type

BY1-C/3+1-320-20

BY1-C/2+1-320-20

Test to

IEC61643-1

IEC61643-1

class

C

C

Rated voltage Un (V)

380

220

Max continuous operating voltage Uc (V)

320

385

420

550

320

Protection level Up (KV)

≤1.5

≤2.0

≤2.0

≤2.5

≤1.5

Max continuous operating current (A)

300

20

Nominal discharge current (8/20uS) In (KA)

N-PE20 N-PE40

20

Response time T (ns)

<100

<100

Color (module/N-PE)

Gray/blue

Gray/blue

Protection grade

IP20

IP20

Max back up fuse

32A gl

32A gl


9.BY1-D/2 & BY1-D/4

Type

BY1-D/2

BY1-D/4

Class

D

D

Rated voltage Un (V)

220

380

Max continuous operating voltage Uc (V)

320

<
Surge Proctect Device for Power Distribution System Prev :BY20 Surge protective device
Surge Proctect Device for Power Distribution System Next :BYX-JZ Series Surge Protective Device